Note: The information below is based on extensive in-house research and hands-on testing conducted by our expert technicians.
This guide provides an overview of fan configurations for the Dell PowerEdge R640 server, with detailed insights on both standard and high-performance setups. Proper fan and heatsink configurations are crucial for optimising system performance, cooling efficiency, and overall airflow within the server chassis.
FAN CONFIGURATION GUIDE
Standard High-Performance 150W+ TDP
Configuration | Number of Processors | Heatsink | Processor/DIMM Blank | DIMM Blanks | Maximum Number of DIMM Blanks | Fan |
---|---|---|---|---|---|---|
PowerEdge R640 (2.5 inch hard drives x 10) | 1 | One 1U standard heat sink for CPU ≤ 165 W | Not required | Required for processor 1 | 11 blanks | Five standard fans |
1 | One 1U 2-pipe heat sink for CPU=200/205 W and 150 W/165 W FO* | Required | Eight high-performance fans | |||
2 | Two 1U standard heat sink for CPU ≤ 165 W | Not required | Eight standard fans | |||
2 | Two 1U 2-pipe heat sink for CPU=200/205 W and 150 W/165 W FO* | Not required | Required | 22 blanks | Eight high-performance fans | |
PowerEdge R640 (2.5 inch hard drives x 10 with NVMe drives) | 2 | Two 1U standard heat sink for CPU ≤ 165 W | Not required | Eight high-performance fans | ||
2 | Two 1U 2-pipe heat sink for CPU=200/205 W and 150 W/165 W FO* | Not required | Required | 22 blanks | Eight high-performance fans | |
PowerEdge R640 (2.5 inch hard drives x 8) + (3.5 inch hard drives x 4) | 1 | One 1U standard heat sink for CPU ≤ 165 W | Not required | Required for processor 1 | 11 blanks | Five standard fans |
1 | One 1U 2-pipe heat sink for CPU=150 W/165 W FO* | Required | Eight high-performance fans | |||
1 | One 1U 2-pipe heat sink for CPU=200/205 W | Required | Eight high-performance fans | |||
2 | Two 1U standard heat sink for CPU ≤ 165 W | Not required | Eight standard fans | |||
2 | Two 1U 2-pipe heat sink for CPU=150 W/165 W FO* | Not required | Eight high-performance fans | |||
2 | Two 1U 2-pipe heat sink for CPU=200/205 W | Not required | Required | 22 blanks | Eight high-performance fans | |
PowerEdge R640 (3.5 inch hard drives x 4) with NVMe drives x 2 in the rear | 2 | Two 1U standard heat sink for CPU ≤ 165 W | Not required | Eight standard fans | ||
2 | Two 1U 2-pipe heat sink for CPU=155 W/165 W FO* | Not required | Eight high-performance fans | |||
2 | Two 1U 2-pipe heat sink for CPU=200/205 W | Not required | Required | 22 blanks | Eight high-performance fans |