This guide provides an overview of fan configurations for the Dell PowerEdge R640 server, with detailed insights on both standard and high-performance setups. Proper fan and heatsink configurations are crucial for optimising system performance, cooling efficiency, and overall airflow within the server chassis.

FAN CONFIGURATION GUIDE

Standard High-Performance 150W+ TDP

Configuration Number of Processors Heatsink Processor/DIMM Blank DIMM Blanks Maximum Number of DIMM Blanks Fan
PowerEdge R640 (2.5 inch hard drives x 10) 1 One 1U standard heat sink for CPU ≤ 165 W Not required Required for processor 1 11 blanks Five standard fans
1 One 1U 2-pipe heat sink for CPU=200/205 W and 150 W/165 W FO* Required Eight high-performance fans
2 Two 1U standard heat sink for CPU ≤ 165 W Not required Eight standard fans
2 Two 1U 2-pipe heat sink for CPU=200/205 W and 150 W/165 W FO* Not required Required 22 blanks Eight high-performance fans
PowerEdge R640 (2.5 inch hard drives x 10 with NVMe drives) 2 Two 1U standard heat sink for CPU ≤ 165 W Not required Eight high-performance fans
2 Two 1U 2-pipe heat sink for CPU=200/205 W and 150 W/165 W FO* Not required Required 22 blanks Eight high-performance fans
PowerEdge R640 (2.5 inch hard drives x 8) + (3.5 inch hard drives x 4) 1 One 1U standard heat sink for CPU ≤ 165 W Not required Required for processor 1 11 blanks Five standard fans
1 One 1U 2-pipe heat sink for CPU=150 W/165 W FO* Required Eight high-performance fans
1 One 1U 2-pipe heat sink for CPU=200/205 W Required Eight high-performance fans
2 Two 1U standard heat sink for CPU ≤ 165 W Not required Eight standard fans
2 Two 1U 2-pipe heat sink for CPU=150 W/165 W FO* Not required Eight high-performance fans
2 Two 1U 2-pipe heat sink for CPU=200/205 W Not required Required 22 blanks Eight high-performance fans
PowerEdge R640 (3.5 inch hard drives x 4) with NVMe drives x 2 in the rear 2 Two 1U standard heat sink for CPU ≤ 165 W Not required Eight standard fans
2 Two 1U 2-pipe heat sink for CPU=155 W/165 W FO* Not required Eight high-performance fans
2 Two 1U 2-pipe heat sink for CPU=200/205 W Not required Required 22 blanks Eight high-performance fans

Categories: Knowledge Base Dell PowerEdge R640 Articles Dell